<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-13 15-49-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 5/5, 59 dBuV hr3
Pilot RDS Phase Difference
6.2 kHz 7.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 77 kHz 18944 33,8207
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
6,0 dBr 7,08 dBr 7,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" hr3 " D3C2 10 (Pop M) 1 0 1 1 --:--
RT
"MPB R1 00s10s Liminka 104.3MHz "
AF EON
-
FM Scope Max at: 77 kHz MIN: 13 kHz % above 76 kHz: 33,8207 Acquired: 2026/01/13 15.48.49 Total samples: 18944 Equivalent time: 0:15:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 7,9 dBr MIN: 6,0 dBr AVE: 7,08 dBr % above 12,2 dBr: 0,0 Last value: 7,4 dBr (2026/01/13 15.48.49) 15.34 15.36 15.38 15.40 15.42 15.44 15.46 15.48 0 2 4 6 8 Pm [dBr]